Non-Invasive Ventilation Solution
The newest addition to the SV-Series Portfolio. The SV70 Ventilator addresses the evolving needs in non-invasive ventilation, underscoring Mindray’s commitment to advancing respiratory care.
| Mindray SV70 | Philips V60 | |
|---|---|---|
| Available Modes | CPAP, S, S/T, P-A/C, VAPS, PPV, O2 Therapy | CPAP, S/T, PCV, AVAPS, PPV |
| Circuit | Single Limb | Single Limb |
| Controlled Parameters | ||
| CPAP | 4 to 25 cmH2O | 4 to 25 cmH2O |
| IPAP | 4 to 40 cmH2O | 4 to 40 cmH2O |
| EPAP | 4 to 25 cmH2O | 4 to 25 cmH2O |
| Pressure Support | 4 to 40 cmH2O | N/A |
| Pressure Backup | 4 to 40 cmH2O | N/A |
| O2 % | 21 to 100 vol.% | 21 to 100 vol.% |
| Tidal Volume | 200 to 2000 mL | 200 to 2000 mL |
| Rate | 4 to 60 min | 4 to 60 min |
| Apnea Backup | 4 to 60 min | |
| Inspiratory Time | 0.30 to 3.00 s | 0.30 to 3.00 s |
| Pmin (VAPS) | 5 to 30 cmH2O | 5 to 30 cmH2O |
| Pmax | 6 to 40 cmH2O | 6 to 40 cmH2O |
| TVMax (VAPS) | 200 to 3500 mL | 200 to 3500 mL |
| PPV% | 0 to 100% | 0 to 100% |
| Max R | 0 to 50 cmH2O/(L/s) | 0 to 50 |
| Max E | 0 to 100 cmH2O/L | 0 to 100 |
| Ramp Time | Off, 5 to 45 | Off, 5 to 45 |
| Slope | 1 to 5 min | 1 to 5 min |
| Oxygen Therapy Flow | 2 to 60 L/min | N/A |
| Technical Specifications | ||
| Battery Backup | 6 Hours | 6 Hours |
Yes. The Mindray SV70 is a comparable — and in some cases expanded — replacement for the Philips V60, preserving familiar workflows while adding additional capabilities. Please see our comparison chart above for detailed information.
Yes. The Mindray SV70 uses a single-limb circuit, the same configuration found on the Philips V60. This shared design makes the SV70 a natural replacement and simplifies the transition for hospital clinicians, since existing circuit setup, handling, and workflow knowledge carries over directly with no relearning curve.
As a hospital non-invasive ventilator, the SV70 pairs its single-limb circuit with a full range of mask interfaces and built-in leak management for innovative non-invasive ventilation.
Key single-limb capabilities include:
This combination makes the SV70 a dependable non-invasive ventilation device for hospitals replacing the Philips V60 while keeping clinical operations consistent.
The Mindray SV70 is a professional-grade non-invasive ventilator (NIV) designed for adult and pediatric patients in hospital and clinical settings. It delivers six ventilation modes — CPAP, S, S/T, P-A/C, VAPS, PPV, as well as O2 Therapy — supported by EasySync™ synchrony enhancement technology and a 15.6-inch touchscreen interface. The SV70 is purpose-built for patients with respiratory failure, chronic respiratory insufficiency, or obstructive sleep apnea who require non-invasive ventilation support. It is intended for use in professional healthcare facilities and supports patients with a minimum body weight of 20 kg across both invasive and non-invasive configurations.
The Mindray SV70 NIV ventilator uses widely recognized ventilation terminology such as VAPS (Volume Assured Pressure Support), which
aligns with commonly used concepts in non-invasive ventilation. This helps clinicians quickly interpret settings and adapt to the system, especially those transitioning from the V60.
The Mindray SV70 is designed for adult and pediatric patients (≥20 kg) who require non-invasive ventilation support, including those experiencing acute or chronic respiratory insufficiency or obstructive sleep apnea.
The Mindray SV70 is a suitable replacement for the Philips V60 BiPAP ventilator. As a purpose-built hospital non-invasive ventilator (NIV), the SV70 operates on a single-limb circuit and delivers a comprehensive set of clinical capabilities — making it an operationally sound choice for facilities transitioning to a new NIV platform.
The SV70 supports six ventilation modes — CPAP, S, S/T, P-A/C, VAPS, PPV, as well as O2 Therapy — covering the full clinical range required for adult and pediatric patients with respiratory failure, chronic respiratory insufficiency, or obstructive sleep apnea. Key clinical capabilities include:
The SV70 is launching in September for professional healthcare facilities that demand a dependable, full-featured NIV ventilator built to meet the demands of modern respiratory care.
The Mindray SV70 hospital-grade non-invasive ventilator offers a comprehensive set of modes, including:
These modes provide flexibility for a wide range of clinical scenarios.
When evaluating a replacement hospital non-invasive ventilator, clinicians often look for continuity in ventilation modes, patient support capabilities, safety features, and workflow integration. The Mindray SV70 NIV ventilator provides a comprehensive set of modes, monitoring, and connectivity to support clinical continuity in non-invasive ventilation.
The Mindray SV70 helps to minimize transition complexity for hospitals replacing the V60. Both devices use a single-limb circuit, provide 6 hours of battery backup, and share identical ranges across all core ventilation parameters — meaning existing clinical protocols, alarm limits, and parameter targets transfer directly without reconfiguration.
The shared specifications that simplify transition include:
With a user-friendly touchscreen interface, logical menu structure, and commonly used ventilation modes (CPAP, S, S/T, P-A/C, VAPS, PPV), the Mindray SV70 supports fast onboarding for clinical teams learning a new hospital non-invasive ventilator.
The Mindray SV70 features a user-friendly touchscreen interface, customizable settings, and integrated alarm systems. These features support efficient clinician workflows when implementing a new non-invasive ventilation device into daily use.