2nd Level Hero Image 1920x750 - mindray-non-invasive-ventilators-1920x750-na

Non-Invasive Ventilators

For Flexible Respiratory Support

Clinicians across critical care, emergency medicine, and step-down care regularly encounter patients whose respiratory status demands non-invasive ventilation (NIV). The various scenarios for NIV include, but are not limited to, acute exacerbations of chronic obstructive pulmonary disease (COPD), acute respiratory failure, post-extubation support, and immunocompromised patients for whom intubation may carry an elevated risk. It is also widely used for patients with Do Not Intubate (DNI) orders.

When used appropriately in patients and clinical scenarios, an NIV machine is a clinical tool that supports lung-protective practice, may help reduce the risk of ventilator-associated complications, and may help avoid the need for intubation in select patient populations. As with all ventilatory strategies, patient selection, clinical judgment, and ongoing monitoring remain essential.

Mindray North America offers the SV70 Ventilator as part of its respiratory care portfolio, a platform that supports clinical teams navigating the demands of non-invasive ventilation across professional healthcare settings.

Where Non-Invasive Ventilation Fits in the Clinical Workflow

Clinical teams use non-invasive ventilation devices across various care environments, including the emergency department (ED), intensive care unit (ICU), step-down and intermediate care units, general care floors, and the post-anesthesia care unit (PACU).

Respiratory therapists and intensivists managing NIV-dependent patients often deal with the need for frequent mode adjustments as patient status evolves and interface fit challenges that affect efficacy and patient comfort. They must also maintain sustained vigilance to monitor patient-ventilator synchrony in spontaneously breathing individuals. Small delays or device-related friction can accumulate over a shift, pulling clinical attention away from the bedside. Mindray approaches these realities as a partner to clinical teams, supporting them across these environments.

  • The Mindray SV70
    Non-Invasive Ventilator

    The SV70 is built around the specific demands that non-invasive ventilation places on clinical teams. Managing interface leaks, both intentional and unintentional, is an ongoing task in NIV therapy, and maintaining patient comfort and synchrony often requires frequent adjustments throughout a shift.

    Setup needs to be fast because time spent configuring a device is time away from the patient and can delay patient care, which could result in medical decline. Our non-invasive ventilation machine addresses each of these realities for use in professional healthcare facilities.

    Sv70 Non Invasive Ventilator

Features That Support ICU Workflows

The SV70's capabilities include:

  • Mode flexibility for varied patient presentations: Our non-invasive solution supports multiple modes, including continuous positive airway pressure (CPAP), spontaneous (S), spontaneous/timed (S/T), pressure-assist/control (P-A/C), volume assured pressure support (VAPS), proportional pressure ventilation (PPV), as well as high flow oxygen therapy. This mode breadth helps clinicians adapt to different clinical needs with a single device
  • Leak management and synchrony support: Since mask leaks occur in NIV therapy, the SV70 offers automatic leakage management. This feature dynamically adjusts the delivered flow in proportion to real-time airway pressure, helping maintain target pressure delivery. The SV70's EasySync™ synchrony enhancement technology supports triggering responsiveness through waveform-based analysis to help sustain synchrony and reduce the patient and device events that drive unnecessary alarms and cause clinician fatigue
  • Intuitive interface and display: The SV70 features a 15.6-inch TFT LCD touch screen with 1920×1080 resolution, supported by a master control knob for parameter confirmation. Ventilation modes and parameters are accessible from the main screen, facilitating adjustments and navigation and supporting clinical workflows
  • Monitoring and trending to assist clinical decision making: Our NIV ventilator displays real-time waveforms and measured parameters, and supports up to 192 consecutive hours of graphic and tabular trend data, providing clinical teams with the longitudinal view needed to detect changes in patient status. Integrated SpO₂ and CO₂ monitoring modules (optional) facilitate continuous physiological surveillance without requiring separate bedside monitors. The ROX index is supported when SpO₂ monitoring is active during O2 therapy, alerting clinicians for the potential need to escalate care during High Flow Oxygen Therapy (HFOT)
Patient Populations Served

Our hospital non-invasive ventilator serves adult and pediatric patients with a minimum body weight of 20 kg who are spontaneously breathing individuals presenting with respiratory failure, chronic respiratory insufficiency, or obstructive sleep apnea.

Patient Populations Served

Pediatric patients may present with anatomical and physiological considerations different from those of adult patients, including smaller anatomical structures that affect interface selection and delivered volumes, and a greater susceptibility to motion-related artifacts during monitoring. We encourage clinical teams to review all applicable parameters, interface selection, and alarm limit settings when transitioning between patient populations, in accordance with their institution's protocols and applicable clinical guidelines.

Contraindications for NIV include respiratory or cardiac arrest, inability to protect the airway due to decreased consciousness, risk of aspiration, or excessive secretions, facial trauma or deformity preventing mask seal, and severe agitation or lack of patient cooperation, among others. Patients with untreated pneumothorax, active vomiting, or signs of gastrointestinal bleeding are also not appropriate candidates for NIV. Clinicians should review all contraindications outlined in the SV70 Operator's Manual and their institution's clinical protocols prior to initiating therapy.

Mindray CARE Team Support

When you invest in Mindray solutions, you gain access to the Mindray CARE Team — a service organization dedicated solely to ensuring you get the most use out of your solutions and your patients get the most out of their care. Our dedicated field service team and in-house technical support organization represent one of the largest direct service teams in the industry.

Purchase from Mindray includes comprehensive clinical training and 24/7 remote technical support.

Get Dedicated Support >>

A Long-Term Partner for Respiratory Care

Since our founding in 1991, Mindray has upheld our commitment to service, dependability, and quality. We prioritize our partners with post-sale support that includes service agreement options and repair services. Our ventilators are backed by a comprehensive warranty, allowing your clinical teams to use the investment with confidence. When a product approaches its end of service life, Mindray provides advance notice and offers programs to help you move to new-generation solutions with minimal disruption to your operations.

We invest 10% of our annual revenue in R&D to deliver high-quality solutions. The Mindray CARE Team has received a 97% customer satisfaction rating, demonstrating our ability to provide trusted services. Many of the top 100 hospitals in the U.S. depend on our solutions, reflecting the confidence that leading healthcare institutions have placed in Mindray.

  • Connect With Mindray to Discuss Non-Invasive Ventilation

    Our mission is to advance medical technologies to make healthcare more accessible, and that commitment shapes how we work with every clinical and health system partner. If you are a clinical or biomedical leader exploring NIV ventilator options for your facility, our team is available to provide product information, schedule demonstrations, and discuss how the SV70 may fit within your clinical environment. Connect with a Mindray representative today to get started.

    Connect with Mindray to Discuss Non Invasive Ventilation
false