of 1855 patients who died before hospital discharge were not admitted to critical care at any stage after surgery [1].
73%
Wearable devices provide a safer and more comfortable monitoring experience, but their accuracy and usability, and the reliability and security of wireless signal transmission can bring great
challenges to clinical application.
To meet these challenges, Mindray has developed the mWear wearable patient monitor. With simple clinical application in multiple scenarios, mWear provides accurate, comprehensive monitoring data.
Medical-grade Wearable Monitoring
A refined design and medical-grade algorithm give mWear the ability to enhance patient safety.
Refined design
Comfortable to wear
Complete wireless interconnectivity
Reliable design
IP22 Waterproof
Resistant to 48 kinds of disinfectants
Medical-grade monitoring
Multi-parameter monitoring
Innovative health parameters
Ring SpO2 sensor
Normal hand movement with greater comfort
Accurate and Reliable Multi-Parameter Monitoring
Backed by years of successful research and development, Mindray provides accurate and reliable multi-parameter monitoring for clinical teams.
Anti-Motion Algorithm
Mindray's innovative patented technology[2] improves the motion artefact performance of mWear to significantly increase parameter accuracy. .
Health Parameter Monitoring
Innovative health parameter: Specialised algorithm based on clinical evidence to monitor patient's exercise and sleep time;
Identify four patient statuses: Falls, exercise, sleep, and rest.
Rising to the challenge
Wearable devices are well accepted by patients, and clinical staff have called for increased accuracy and usability of such devices. [3].
Rising to the challenge
Wearable devices are well accepted by patients, and clinical staff have called for increased accuracy and usability of such devices.[3].
Smooth Workflow
How can we make wearable devices easier to use for patients and clinical staff? Informed by real clinical needs, Mindray is tackling these challenges in three ways:
Monitoring Preparation
Patient Monitoring
Charging & Device Management
Pairing through a single touch
Patient information auto bound through PDA scanning
Unified management and viewing through central station
Patient information auto bound through PDA scanning
Patient Monitoring
Unified management and viewing through central station
EWS Dashboard Screen
Innovative Wearable Mode
Falls Warning
Emergency Monitoring
Charging & Device Management
Long lasting: at least 48 hours battery life
Replace the battery with a single hand
Centralised charging. Clear charging instruction
Large volume storage
Reliable and Accessible IT Solution
Homehospital application*
mWear also extends to the home through the App so that patients are safely monitored at home.
Dedicated app design
App sends the data back to the central station in hospital for unified management of patient data in the ward
Independent charging pod
* Will go online on 2023.01.01
Accessible IT Solution
mWear uses the same centralised monitoring system whether the patient is in hospital or at home. All data can be displayed, analysed, and sent to the 3rd-party EPR via Mindray's standard interface for a more comprehensive picture of patient health.
[1] Pearse R M, Rui P M, Bauer P, et al. Mortality after surgery in Europe: a 7 day cohort study[J]. Lancet, 2012, 380(9847): 1059-1065. [2] Technical algorithm patent No.: EP 18921425.7, PCT/CN2018/088982 [3] Leenen JPL, Dijkman EM, van Dijk
JD, et al.Feasibility of continuous monitoring of vital signs in surgical patients on a general ward: an observational cohort study. BMJ Open 2021;11:e042735.
{"enabled":true,"consentTitle":"We value your privacy","message":"This content is hosted by an external provider. Enabling it may allow the provider to process your personal data and set cookies.\r\n","acceptLabel":"Allow \u0026 Continue","alwaysAcceptLabel":"Always trust and apply default supplier settings.","consentState":"undecided"}