Hematology Controls and Calibrators

Quality, Ready-to-run and Convenient

2021-10-12_092833
Mindray's hematology controls and calibrators are the original standards with which to evaluate the precision and accuracy of hematology analyzers. Backed up by world-class development and manufacturing, these hematology controls and calibrators offer the assurance of highest quality from your lab results. All of these hematology controls and calibrators feature long-term stability and ready-to-run tubes, and are thus convenient to use.

Calibrator & Control

Features

BC-3D Hematology Control

  • Tri-level controls designed specifically for all 3-diff analyzers
  • With three-part WBC differential· 105-day closed vial stability;
  • 14-day open vial stability
  • Packaged in 3mL pierceable screw cap tubes
Package
1 Low, 1 Normal, 1 High
2 Low, 2 Normal, 2 High
6 Low
6 Normal
6 High

B30 Hematology Control

  • Tri-level controls designed specifically for all 3-diff analyzers
  • With three-part WBC differential
  • 120-day closed vial stability;
  • 14-day open vial stability
  • Packaged in 3mL pierceable screw cap tube
Package
1 Low, 1 Normal, 1 High
2 Low, 2 Normal, 2 High
6 Low
6 Normal
6 High

BC-5D Hematology Control

  • Tri-level controls designed specifically for BC-5800, BC-5600, BC-5390, BC-5300, BC-5310, BC-5380, BC-5180, BC-5000, BC-5120, BC-5130, BC-5150, BC-5000Vet, BC-5300Vet, BC-5100Vet analyzers
  • With five-part WBC differential
  • Package · 75-day closed vial stability;
  • 14-day open vial stability
  • Packaged in 3mL pierceable screw cap tubes
Package
2 Low, 2 Normal, 2 High
6 Low
6 Normal
6 High
12 Low
12 Normal
12 High
4 Low, 4 Normal, 4 High

B55 Hematology Control

  • Tri-level controls designed specifically for BC-5800, BC-5600, BC-5390, BC-5300, BC-5310, BC-5380, BC-5180, BC-5000, BC-5120, BC-5130, BC-5150, BC-5000Vet, BC-5300Vet, BC-5100Vet analyzers
  • With five-part WBC differential
  • 90-day closed vial stability;
  • 14-day open vial stability
  • Packaged in 3.5ml pierceable screw cap tubes
Package
1 Low, 1 Normal, 1 High
6 Low
6 Normal
6 High
2 Low, 2 Normal, 2 High

BC-6D Hematology Control

  • Tri-level controls designed specifically for BC-6800, BC-6800Plus, BC-6600, BC-6200, BC-6000
  • with five-part WBC differential
  • 75-day closed vial stability;
  • 15-day or 15 pierces open vial stability
  • Packaged in 4.5mL pierceable screw cap tubes
Package
6 Low
6 Normal
6 High
2 Low, 2 Normal, 2 High

BC-RET Hematology Control

  • Tri-level controls designed specifically for BC-6800, BC-6800Plus, BC-6600, BC-6200
  • 75-day closed vial stability;
  • 15-day or 15 pierces open vial stability
  • Packaged in 4.5mL pierceable screw cap tubes
Package
6 Low
6 Normal
6 High
2 Low, 2 Normal, 2 High

BC-BF Hematology Control

  • Tri-level controls designed specifically for BC-6000, BC-6000Plus, BC-6100, BC-6100Plus, BC-6200, BC-6800Plus, BC-6600Plus, BC-6700Plus, BC-6600, BC-6800
  • Unopened tubes are stable through the expiration date
  • 30-day open vial stability
  • Packaged in 3mL pierceable screw cap tubes
Package
Low 3mL× 2 + Normal 3mL× 2 + High 3mL× 2
Low 3mL× 1 + Normal 3mL× 1 + High 3mL× 1

SC-CAL Plus Hematology Calibrator

  • Calibrators designed to use on all BC- analyzers
  • Assay values for WBC, RBC, PLT, HGB and MCV· 45-day closed vial stability
  • 7-day open vial stability
  • Packaged in 3mL pierceable screw cap tubes
Package
2 tubes

S30 Plus Hematology Calibrator

  • Assay values for WBC, RBC, PLT, HGB and MCV
  • 90-day closed vial stability
  • 7-day open vial stability
  • Packaged in 3mL pierceable screw cap tubes
Package
1 tubes
2 tubes

S50 Plus Hematology Calibrator

  • Calibrators designed to use on all 5-part differential BC- analyzers
  • Assay values for WBC, RBC, PLT, HGB and MCV· 50-day closed vial stability
  • 7-day open vial stability
  • Packaged in 3mL pierceable screw cap tubes
Package
2 tubes
6 tubes

ASO/CRP/RF Triple Control

  • Controls designed specifically for internal quality control of C-reactive protein concentration measurement in human whole blood
  • To be used with CRP-M100, BC-5390CRP, BC-5310CRP, BC-5100CRP, BC-5180CRP analyzers
  • 12-month closed vial stability; 30-day open vial stability
  • Low & high level with assay values
  • Packaged in 1mL screw cap tubes, total with 6 tubes (Low level* 3, high level *3)
 

C-reactive Protein (CRP) Calibrator

  • Calibrators designed for calibration of C-reactive protein measurement in human whole blood.
  • To be used with CRP-M100, BC-5390CRP, BC-5310CRP, BC-5100CRP, BC-5180CRP analyzers
  • 12-month closed vial stability; 14-day open vial stability
  • Five concentration levels with assay values
  • Packaged in 0.5mL screw cap tubes, total with 5 tubes