Auto Hematology Analyzer

BC-5150

A “CUTE” 5-part

A “CUTE” 5-part

Based on Mindray’s continuous innovation in hematology field, BC-5150 is especially tailored to assist diagnostic labs who need full CBC + 5-part results, with relatively low daily sample volume, restricted lab space and tight budget.

 

As the lightest and most compact 5-part hematology analyzer so far from Mindray, BC-5150 is a highly user-friendly and innovative analyzer that offers cost efficient CBC and 5-part white cell differential results. It is targeted to fulfill and exceed the demands of our global customers by providing more accurate, more efficient and more innovative solutions for labs.

glp13_img1

Compact

Two kinds of lyse reagents are located inside of BC-5150, which helps the small labs to save space.

glp13-s3

Utility

The 10.4 inch TFT touch screen with a wide viewing angle, brings convenience to clinicians. Users can complete all instrument operations on the screen, practically eliminating the need for an external PC.
BC-5150 inherits it’s convenient and proven powerful software design from BC-6800 and BC-3600 platforms, the friendly interface is ideal for small sized labs.
Running capillary blood through the sample probe directly is more convenient for the users in children’s hospitals, etc. For Prediluted mode, BC-5150 has higher dilution ratio than other 5-part hematology analyzer, thus it brings a better mixing effect.
Running capillary blood through the sample probe directly is more convenient for the users in children’s hospitals, etc. For Prediluted mode, BC-5150 has higher dilution ratio than other 5-part hematology analyzer, thus it brings a better mixing effect.
There’s NLR parameter in each CBC+DIFF result. Neutrophil-to-lymphocyte ratio (NLR) is calculated by dividing neutrophil count by lymphocyte count, usually from peripheral blood sample. In laboratory medicine, NLR is used as a marker of subclinical inflammation. According to clinical studies, NLR can be used as a prognostic factor of severe illness in COVID-19 patients.
BC-5150 supports bi-directional LIS with test results and patient information. HL7 protocol is supported as well.

Technology

Compared with traditional helium neon laser or argon laser,semi-conductor laser has smaller size,lower cost and longer life cycle.
Improved DC impedance technology is used to count and size the RBC and PLT. The smaller counting aperture (50 μm in diameter) provides better performance on samples with low PLT.

Efficient

Only three routine reagents are required. These have 2 years shelf life and also less consumed by BC-5150. Original QC and calibrator are also provided to ensure the hematology analyzer’s traceability and testing quality.